Gree inverter AC error codes: full list and meanings

When a Gree AC finds a fault, the indoor unit's display shows a two-character code, such as H3 or E6. The table below explains each code, so you can tell whether it is a small issue or a job for a mistri.

Updated 11-Nov-2026

These codes mean the same on most Gree inverter split AC models (such as the Pular and Fairy series). Some models differ slightly, so check your AC's manual or model number too.

For any code, try this first

  • Turn the AC off with the remote, then switch off the main switch or breaker for 5 minutes. Turn it back on and see if the code returns.
  • Take out the indoor unit's filters, wash them with water, let them dry and put them back.
  • Check that nothing blocks air around the outdoor unit, such as clothes, a wall or rubbish.
  • If the mains voltage is very low or very high, look at the stabilizer's light. Don't run the AC until the voltage is normal.

Safety: never reach into an electrical panel, board, gas pipe or the inside of an inverter yourself. You can get a shock or release gas. This is a mistri's job.

Fault codes

These show on the indoor unit's display, and the AC or its compressor stops.

CodeMeaning
E1Refrigerant pressure went too high (high pressure protection). Details
E2Indoor coil is close to freezing (anti-freeze protection).
E3Low refrigerant pressure: low gas, a leak or a blockage.
E4Compressor discharge temperature too high. Details
E5Overcurrent protection. On some older models, low voltage. Details
E6Indoor and outdoor units have lost communication. Details
E8High temperature or overload protection.
EEMemory chip (EEPROM) fault on the board.
F0Low refrigerant or leak protection. Details
F1Indoor room temperature sensor open or shorted.
F2Indoor coil (evaporator) temperature sensor open or shorted. Details
F3Outdoor ambient temperature sensor open or shorted.
F4Outdoor coil (condenser) temperature sensor open or shorted.
F5Compressor discharge temperature sensor open or shorted.
H3Compressor overload protection: the compressor overheated and stopped. Details
H4System abnormal (usually from heat or overload).
H5IPM protection: the module driving the compressor detected overcurrent. Details
H6Indoor fan motor is not running or not reporting back.
H7Compressor out of step with the drive (desynchronizing).
HCPFC protection: fault in the part that conditions power for the compressor. Details
L3Outdoor DC fan motor fault or blocked fan.
LCCompressor failed to start.
LPIndoor and outdoor units don't match each other.
PHDC bus voltage too high (often high mains voltage).
PLDC bus voltage too low (often low mains voltage).
C5Jumper cap on the board is missing or loose.

Not a fault, just a status

This code appears during normal work. It does not need a mistri.

CodeMeaning
H1Defrosting during heating. Not a fault; it ends by itself.

Common questions

How do I reset a Gree AC error code?

Turn the AC off with the remote, switch off the main switch or breaker for 5 minutes, then turn it back on. If the cause has gone, the code clears. If it comes back, the fault is still there and a mistri should look at it.

Does an error code always mean the gas has run out?

No. Only a few codes relate to gas, such as F0, E3 and often E4. Most others are about sensors, wires, fans, boards or voltage. Before refilling gas, ask the mistri to measure the pressure first.

Code still there?