Gree H3 error ka matlab kya hai?
H3 ka matlab hai ke compressor par laga overload protector khul gaya, yaani compressor zyada garam ho gaya ya zyada load par chala. AC ne compressor rok diya taa ke woh jal na jaye. Thanda hone par AC aksar khud dobara chal parta hai.
H3 code kyun aata hai?
- Gas kam hai, is liye compressor garam rehta hai.
- Bahar wale unit ki jaali gandi hai ya unit dhoop aur band jagah par hai.
- Bijli ka voltage kam hai.
- Overload protector ki taar dheeli hai ya protector kharab hai.
H3 aaye to aap khud kya check kar sakte hain?
- AC band karein aur 30 minute tak compressor ko thanda hone dein, phir chalayein.
- Bahar wale unit ke aas paas jagah khuli karein aur dekhein ke pankha chal raha hai.
- Voltage kam ho to AC band rakhein.
Hifazat: bijli ke panel, board, gas pipe ya inverter ke andar khud haath na dalein. Is se karant lag sakta hai ya gas nikal sakti hai. Yeh kaam mistri ka hai.
Mistri kab bulayein?
H3 roz aaye to mistri bulayein. Gas ka pressure, condenser ki safai aur compressor ki taarein check karna mistri ka kaam hai. Bar bar overload hone se compressor jal sakta hai.