Gree H5 error ka matlab kya hai?
Inverter AC mein ek power module (IPM) compressor ki speed chalata hai. H5 ka matlab hai ke is module ne zyada current ya kharabi pakri aur compressor rok diya. Aksar wajah bahar ki garmi, gandi coil ya kam voltage hoti hai, lekin board ya compressor bhi kharab ho sakta hai.
H5 code kyun aata hai?
- Bahar wale unit ki coil gandi hai ya hawa nahi mil rahi.
- Bijli ka voltage kam hai ya jhatke de raha hai.
- Gas ka pressure theek nahi.
- Bahar wale unit ka board (IPM) ya compressor kharab hai.
H5 aaye to aap khud kya check kar sakte hain?
- Bijli 5 minute band kar ke AC dobara chalayein.
- Bahar wale unit ke aas paas jagah khuli rakhein.
- Voltage ka khayal rakhein. Kam voltage par AC na chalayein.
Hifazat: bijli ke panel, board, gas pipe ya inverter ke andar khud haath na dalein. Is se karant lag sakta hai ya gas nikal sakti hai. Yeh kaam mistri ka hai.
Mistri kab bulayein?
H5 baar baar aaye to mistri bulayein. Board ke andar bijli band karne ke baad bhi current reh sakta hai, is liye bahar wale unit ka cover khud na kholein.